Availability: | |
---|---|
Quantity: | |
PC-150
35-150,4-50mm²
500000/month
Thermoplastic Fibre Glass Reinforced Reinforced nylon
Material : High strength aluminium alloy ,anti-UV plastic
A broad usage in the low voltage insulation lines,leading the branch connection to the main conductor.
T-connection of low voltage insulation wire service and cable branch connection for building distribution system.
The material for the inside body is high strenght aluminum alloy and the insulation cover is used polyvinyl chloride(PVC).The connectors with specially designed contact teeth,are suitable for the connection of aluminium .
Put the main conductor and branch conductor parallel into the teeth grooves of th clamp ,tighten the bolts,piece the insulation of two conductors to mark the conductors connect.
The insulation cover functions as waterproof and sealing perfectly.
At the breaking force of the conductor ,the connector will not be distored and broken.At the rated current and short circuit ,rising temperature of the connector should be less than the connecting conductor .
Modle | Main conductor Cross-section(mm2) | Tap conductor Cross-section(mm2) |
PI-71 | 35-95 | 4-54 |
CD-71 | 35-95 | 4-54 |
PC-150 | 35-150 | 4-50 |
P-71 | 35-95 | 4-50 |
P-72 | 35-95 | 2X(4-50) |
P-150 | 70-150 | 2X(4-54) |
P-151 | 6-150 | 6-95 |
Material : High strength aluminium alloy ,anti-UV plastic
A broad usage in the low voltage insulation lines,leading the branch connection to the main conductor.
T-connection of low voltage insulation wire service and cable branch connection for building distribution system.
The material for the inside body is high strenght aluminum alloy and the insulation cover is used polyvinyl chloride(PVC).The connectors with specially designed contact teeth,are suitable for the connection of aluminium .
Put the main conductor and branch conductor parallel into the teeth grooves of th clamp ,tighten the bolts,piece the insulation of two conductors to mark the conductors connect.
The insulation cover functions as waterproof and sealing perfectly.
At the breaking force of the conductor ,the connector will not be distored and broken.At the rated current and short circuit ,rising temperature of the connector should be less than the connecting conductor .
Modle | Main conductor Cross-section(mm2) | Tap conductor Cross-section(mm2) |
PI-71 | 35-95 | 4-54 |
CD-71 | 35-95 | 4-54 |
PC-150 | 35-150 | 4-50 |
P-71 | 35-95 | 4-50 |
P-72 | 35-95 | 2X(4-50) |
P-150 | 70-150 | 2X(4-54) |
P-151 | 6-150 | 6-95 |